Our expert team has specialised
training & experience to help
find the right solution for your
business.
Inner Range EliteX Standard Keypad | ||
Physical | ||
Housing Dimensions | 152h x 90w x 18d mm | |
Installation Environment | 0 Degrees - 50Degrees C @ 15% to 85% relative humidity (non-condensing) | |
Electrical | ||
Input Voltage | 11V - 14V DC | |
Operational Current at 13.7V DC | 14.4mA (Back-light & LEDS off), 42mA (Back-light & LEDS max brightness) | |
Operations Current @ 13.7V DC SIFER Model | 46mA (Back-light & LEDS off), 186mA (Peak, Back-light & LEDS max brightness) | |
Auxiliary Open Collector Output Current | 18VDC, 500mA maximum each (PTC protected) | |
Display & Indicator Brightness | ||
Display/ Keypad | Variable brightness via programming (Can be turned off) | |
LED Indicators | Variable brightness via programming Indicators & I/Os | |
LED Indicators | 8 | |
Aux Outputs (Open collector) | 2 | |
Universal I/Os | 2 (Input mode is compatible with original Elite, or EOL/Multi-state compatible) | |
Inception Controller | ||
Case Material | ABS plastic< | |
Dimensions | 205mm x 94mm x 36mm | |
Shipping Weight (gross) | 1.2kg | |
Installation Environment | 0°C-50°C @ 15%-90% relative humidity (non-condensing) | |
Power Source - To “DC IN” (recommended): - To “BATT” (alternate method): | 18V to 24VDC 2.5A (e.g. the supplied 24V 2.5A PSU) Note: A 12V, SLA Battery of 7AH to 18AH capacity must be connected to 'BATT' input. 12.8V-14VDC 2.8A (e.g. a separate external battery-backed power supply) Note: "DC IN" should not be connected when powered via the BATT connection | |
Battery (supplied separately) | 12 Volt Sealed Lead-Acid (gel) type - 7 to 18 Amp-Hour | |
Idle Current Consumption - DC IN: (24V DC) - BATT: (DC IN = 0V) Note: Does not include battery charging or current required by any peripheral devices. | 60mA (85mA with Ethernet connected) 110mA (150mA with Ethernet connected) | |
Additional Current Required For: - Built-in Relays: (out 1 ~ out 4) - Inception WiFi Adapter: - Inception 4-Port USB Hub: | 25mA per relay (33mA when Controller powered from "BATT" input) 25mA (40mA when Controller powered from "BATT" input) 20mA (40mA when Controller powered from "BATT" input) Not including current required by any device connected to a USB Port | |
Power Supply Outputs: - V OUT (4-PIN): - V OUT (2-PIN): - LAN +: - READER +: - USB 2.0: - Maximum Combined Current - All Outputs | See notes 1 & 2 below 13.4VDC +/-150mV 750mA max 13.4VDC +/-150mV 1.5A max 13.4VDC +/-150mV 350mA max 13.4VDC +/-150mV 1A max 5VDC 500mA max 2.5 A | |
Battery Charger Output Voltage: | 13.75VDC / Output Current: Up to 500mA | |
Typical Battery Backup Time: - 7AH Battery: - 18AH Battery: - 18AH Battery: | With Ethernet or Wi-Fi + 1 LCD Terminal + up to 200mA for other devices. 16 Hours 40 Hours 24 Hours Configuration as above but up to 500mA for other devices. | |
AC Fail Detect (on "DC IN"): | 16 Hours | |
Output Fuses: | 40 Hours | |
Battery Input Fuse: | 24 Hours Configuration as above but up to 500mA for other devices. | |
Battery Deep Discharge Protection Activated: | 10.4V / Restored: 12.5V | |
Zone Inputs: | 8 | |
Relay Outputs: | 4 (“OUT1-4”) | |
Relay Contact Rating: | 5A 30VDC or AC (See note 2 below) | |
Indicator LED’s: | 11 | |
Alarm Reporting Formats: | ContactID or IR-fast (via T4000 or SkyTunnel) | |
Physical | ||
Enclosure Options | XSmall - 252(L) x 263(W) x 85(D) (mm): Part# 995200XS Small - 252(L) x 358(W) x 85(D) (mm): Part# 995200PE2 or 995200PE3 Medium - 460(L) x 358(W) x 85(D) (mm): Part# 995201PE2, 995201PE3 or 995201PE8 XLarge - 702(L) x 358(W) x 85(D) (mm): Part# 995203PE2, 995203PE3 or 995203PE8 WideBody - 580(L) x 510(W) x 95(D) (mm): Part# 995204PE3 or 995204PE8 Rack Mount - 2RU 680(L) x 420(W) x 85(D) (mm): Part# 995220PE2, 995220PE3 or 995220PE8 | |
PCB Size Code | Integriti "B" size | |
PCB Dimensions | 200(L) x 94(W) x 45(D) (mm) | |
Shipping Weight: | 260grams (Circuit Board and Accessories only) | |
Installation Environment | 0°C - 70°C @15% - 90% Relative humidity (non-condensing) | |
Electrical (For PCB Only) | ||
Power Supply Input | 11V to 14VDC | |
Current Consumption | 60mA standby. 100mA with both Aux relays on NOTE: Current consumption does not include the current required by detectors or other external devices such as buzzers, lamps or any device attached to the DET+, LAN+ and UniBus connections | |
Contact Ratings | ||
Aux Relays | 2 Amps @ 30VDC | |
Connections | ||
Zone Inputs | 8 x Multistate Zone Inputs | |
Aux Outputs | 2 x Relay Output NO|COM|NC | |
Cabinet Tamper | 2 pin connection for cabinet tamper switch | |
UniBus Port | 1 x UniBus Host expansion port | |
RS-485 LAN | 1, Includes LAN+, LAN-, A, B. (LAN addressing set via DIP switches) | |
Siren Outputs | 1 x Internal & 1 x External variable tone Siren Outputs* | |
Power Supply | 1 x Integriti External Power Supply Connection | |
Power Outputs | 4 x 13.75Vdc nominal outputs (DET+/DET- Detector Power) | |
External Power Supply Monitoring (Compatible with IR SMART PSU Devices) | ||
AC Fail | External PS AC Fail | |
Low Battery | External PS Low Battery | |
LAN Fuse | External PS LAN Fuse | |
Detector Fuse | External PS Detector Fuse | |
Low Volts | External PS Low Volts | |
PSU Fail | External PS Fail | |
T4000 Lite Security Communicator | ||
Physical | ||
Size | 101(L) x 79(W) x 23(D) (mm) (Not including connectors) | |
Shipping Weight | 195g | |
Enclosure Type | ABS plastic | |
Installation Environment | 0°C - 50°C @15% - 90% relative humidity (non-condensing) | |
LED Indicators | ||
Status Indicators | 5 | |
Alarm Communications | ||
Alarm Formats | Contact ID, IRFast, IRFast + Text | |
PABX | ||
Max PABX line Voltage | 65V RMS | |
Max PABX Current | 30mA | |
PABX Output Level | -10dBm | |
Max RF Power | 2 watts | |
Power Specifications | ||
Input | 12-24VDC, 150mA Nominal | |
Current consumption @ 13V DC | 115mA (Idle) + 30mA (GSM Online) | |
Minimum operating voltage | 8V DC | |
Low volts sense voltage (typical) | 11.0V | |
Fuse | PTC protection + on-board fuse (non-replaceable) | |
Zone input | 3 Software configurable (EOL or Non-EOL) | |
Open Collector output (OUT) current | 3 100mA DC per output |
Model | Description | Price | Stock | |
---|---|---|---|---|
IK-INC5 | Controller Kit 5, Med Enclosure, Battery, T4000 Lite, Keypad, Expander Module | $2,625.70 | Add to Cart |
Filename | Size | ||
---|---|---|---|
medium enclosure Datasheet.pdf | 797KB | Download | |
998535 Datasheet.pdf | 907KB | Download | |
996005PCBK Datasheet.pdf | 2MB | Download | |
996300AU Datasheet.pdf | 2MB | Download | |
995400 Datasheet.pdf | 1MB | Download |
Access Control > Controllers
Access Control > Controllers
Access Control > Controllers
Most of our shipments are delivered using Australian courier companies such as Toll, Star Track Express, TNT or Border Express. Over 90% of orders are delivered within 2 business days.
Contact our sales team to see if the item you want to purchase is available to collect from the warehouse nearest to you.
We have many international clients. Contact our sales team for delivery costs and times.
POSMarket can provide your business with the hardware, software, services and consumables you need to take your business to the next level. We can develop custom software for your next project or customise a solution from off-the-shelf software to suit your needs.
Request a Consultation Today