UniBus 2 Door / 2 Reader Expander | ||
Part number | 996535PCB&K | |
Physical | ||
PCB Size Code | Integriti “B†size | |
PCB Size | 200(L) x 94(W) x 45(D) (mm) | |
Height | 20(D) (mm) (45mm with UniBus cable connected) | |
Shipping Weight | 290grams | |
Installation Environment | 0ºC - 70ºC @15% - 90% Relative humidity (non-condensing) | |
Electrical | ||
Power Supply Input | 11V to 14VDC via host module | |
Current Consumption | 40mA idle 110mA both lock relays on 135mA both lock & DOTL relays on NOTE: Current consumption does not include the current required by readers or other external devices such as locks, buzzers, lamps or any device attached to the DOTL, Valid, Invalid, RS-485 Reader and UniBus connections | |
Over Current Protection | Reader +V connections. Protected with self-resetting PTC’s | |
Contact Ratings | ||
Lock Relays | 5 Amps @ 30VDC | |
DOTL Relays | 1 Amp @ 30VDC (Door Open Too Long output) | |
Connections | ||
Lock 1 & 2 | Includes Lock+, Lock-, NO/COM/NC | |
Door 1 & 2 | Includes Reed, 2 x 0v, Tongue, REN, REX, DOTL contacts | |
Wiegand Reader 1 & 2 | Includes Valid, Invalid, 0V, Reader+, D1, D0, ARM | |
Lock Power | Includes Lock+, Lock- connections from external PSU | |
UniBus Port | 3 x UniBus connections for loop-through and connection to host module | |
Power Considerations | The UniBus host module supplies static device current to all connected UniBus devices. | |
Total current consumption is, therefore the sum of all | - Static Current of all connected UniBus devices - Static Current of host module - Host module battery charging current - Card Readers and Ancillary devices connected to DOTL, Valid & Invalid connections | |
Lock Power Considerations | Lock power is supplied directly from an Integriti SMART PSU (Housed in the same enclosure) and is the sum of the maximum current required by all connected locking device hardware. | |
Access Controller (IAC) | ||
Part number | 996035PCB&K | |
Physical | ||
Enclosure Dimensions | Medium - 460(L) x 358(W) x 85(D) (mm): Part# 995201PE3 or 995201PE8 - houses 1 x 996035+ 1 x 996535* XLarge - 702(L) x 358(W) x 85(D) (mm): Part# 995203PE3 or 995203PE8 - houses 1 x 996035 + up to 3 x 996535* WideBody - 580(L) x 510(W) x 95(D) (mm): Part# 995204PE3 or 995204PE8 - houses 1 x 996035 + up to 3 x 996535* Rack Mount - 2RU 680(L) x 420(W) x 85(D) (mm): Part# 995220PE3 or 995220PE8 - houses 1 x 996035 + up to 2 x 996535* | |
PCB Size Code | Integriti "A" size | |
PCB Dimensions | 200(L) x 200(W) x 45(D) (mm) | |
Weight | 8.2 k.g. (In medium enclosure including mains transformer, 7AH battery and cover) | |
Shipping Weight | 700grams (Circuit board & Accessories only) | |
Installation Environment | 0°C - °C @15% - 90% Relative humidity (non-condensing) | |
Electrical (For PCB Only) | ||
Power Supply Input | : 11V to 14VDC (from external Integriti 3Amp or 8Amp SMART PSU) | |
Current Consumption | 150mA standby, 220mA with on-board lock relays on, add 15mA for each active DOTL relay NOTE: Current consumption does not include the current required by readers or other external devices such as locks, buzzers, lamps or any device attached to the DOTL, Valid, Invalid, RS-485 Reader and UniBus connections | |
Reader Head Supply O/P | 5V/13.8V DC, 300mA maximum per reader, 1Amp max for all readers | |
Over Current Protection | Reader +V connections. Protected with self-resetting PTC’s | |
Typical Reader Current | Allow 50~120mA for small Proximity Readers, 120~180mA for standard Proximity Readers (See reader datasheets for specific detail) | |
RS-485 Reader LAN Current | Allow 75~150mA per SIFER reader connected | |
Contact Ratings | ||
Lock Relays | 5 Amps @ 30VDC | |
DOTL Relays | 1 Amp @ 30VDC (Door Open Too Long output) | |
Connections | ||
Ethernet | 10/100 Ethernet Port | |
USB Host | USB type "A" connection | |
USB Slave | USB type "B" connection | |
Port Zero | 5 Pin header for PC or Multipath-IP STU connection | |
Smart Card Slot | For use with Smart Card (System Options Card) | |
Lock 1 & 2 | Includes Lock+, Lock-, NO/COM/NC | |
Door 1 & 2 | Includes Reed, 2 x 0v, Tongue, REN, REX, DOTL contacts | |
Wiegand Reader Ports x 4: | Includes Valid, Invalid, 0V, Reader+, D1, D0, ARM | |
Lock Power Input | Includes Lock+, Lock- connections from external PSU | |
Cabinet Tamper | 2 pin connection for cabinet tamper switch | |
Watchdog Output | 2 pin connection for remote monitoring system | |
UniBus Port | 1 x UniBus Host expansion port for up to 6 local UniBus devices | |
RS-485 LAN | 1, Includes LAN+, LAN-, A, B. (LAN addressing set via DIP switches) | |
RS-485 Reader | 1 Includes LAN+, LAN-, A, B, Auto addressing for SIFER Readers | |
External Power | 10way header block for connection to Integriti power supplies | |
External Power Supply Monitoring (Compatible with IR SMART Power Supplies) | ||
AC Fail | External PS AC Fail | |
Low Battery | External PS Low Battery | |
LAN Fuse | External PS LAN Fuse | |
Detector Fuse | External PS Detector Fuse | |
Low Volts | External PS Low Volts | |
PSU Fail | External PS Fail | |
Medium Enclosure | ||
Part number | 995201PEI | |
Physical | ||
Enclosure Size | 460(L) x 358(W) x 85(D) | |
Cable Entry Points | ||
Top | 3 x 25mm Round Conduit Punch-outs 1 x 25x50mm Punch-out 1 x 50x50mm Punch-out 1 x Power entry | |
Base | 2 x 25mm Round Conduit Punch-outs 1 x Power Entry 1 x DB9 Chassis Mount Point | |
Back | Through wall cable entry behind main plate | |
Powered Versions | 2/3/8Amp See the Integriti 2/3/8Amp PSU Datasheets for PSU Specifications | |
12V 7.0Ah Sealed Lead Acid Battery | ||
Part number | 1200 | |
Cells Per Unit | 6 | |
Voltage Per Unit | 12 | |
Capacity | 6.5Ah@20hr-rate to 1.75V per cell @25 C | |
Weight Approx. | 1.9 Kg | |
Max. Discharge Current | 65A (5 sec) | |
Internal Resistance | Approx. 35 mΩ | |
Operating Temperature Range | Discharge: -20 ~60 °Charge: 0 °C~50°C Storage: -20 C~60 C 0°C | |
Normal Operating Temperature Range | 25 C+/-5 C | |
Float charging Voltage | 13.7 to 13.9 VDC/unit Average at 25 C | |
Recommended Maximum Charging Current Limit | 2.0 A | |
Equalization and Cycle Service | 14.6 to 14.8 VDC/unit Average at 25 C | |
Self-Discharge | Valve Regulated Lead Acid (VRLA) batteries can be stored for o more than 6 months at 25 C. Self f-discharge ratio less than 3% o per month at 25 C. Pleas e charge bat teries before using | |
Terminal | Faston Tab 187(F1)/Faston tab 250(F2) | |
Constainer Material | A.B.S. (UL94-HB) , Flammability resistance of UL94-V2 can be available upon request. | |
Dimensions | 151(L) 65(W) 100(H) |
Model | Description | Price | Stock | |
---|---|---|---|---|
IK-996035M4PS | IAC 4 Door Controller Kit includes 3 Amp SMART PSU | $3,344.00 | Add to Cart |
Access Control > Controllers
Access Control > Controllers
Access Control > Controllers
Most of our shipments are delivered using Australian courier companies such as Toll, Star Track Express, TNT or Border Express. Over 90% of orders are delivered within 2 business days.
Contact our sales team to see if the item you want to purchase is available to collect from the warehouse nearest to you.
We have many international clients. Contact our sales team for delivery costs and times.
POSMarket can provide your business with the hardware, software, services and consumables you need to take your business to the next level. We can develop custom software for your next project or customise a solution from off-the-shelf software to suit your needs.
Request a Consultation Today