1300 737 998
Need Help?

Our expert team has specialised
training & experience to help
find the right solution for your
business.

Call 1300 737 998

Inception IK-INC7

$2,837.45 (incl. GST)

POSMarket SKU: Z15954

IK-INC7: Controller Kit 7, Large Enclosure, Battery, T4000 Lite, Expander & Relay

Controller Kit 7 with large enclosure

Product Rating
Product Overview
This item contains the following components:

1 x Inner Range EliteX Standard Keypad
1 x Inception Controller
1 x Integriti 8 Input 2 Siren I/O LAN Expander (IOEXP)
1 x Integriti UniBus 8 Input Expander to suit ISC / IOEXP
1 x Integriti UniBus 8 Relay Output Expander to suit ISC / IOEXP
1 x Inception to T4000 Security Communicator Interface Cable
1 x Integriti Extra Large Powered Enclosure with 3 Amp Power Supply
1 x Multipath T4000 Lite 4G, Dual Sim, 3 Inputs, 3 Outputs, (Telstra/Optus)
1 x 12V 7.0Ah Sealed Lead Acid Battery

Inner Range EliteX Standard Keypad
The EliteX standard keypad is an elegantly designed terminal that features a clear and easy to read OLED display. Users can utilise the keypad to perform typical operations on the Integriti system including control of security areas, door access, event activity review and controlling the state of outputs.

Inception Controller
Designed to communicate with alarms using modern IP alarm transmission methods. Inception leverages its internet based connectivity to deliver IP alarms to the monitoring station of your choice. Additionally all alarm communication is secured using 128Bit AES encryption to ensure all data is kept private.

Integriti 8 Input 2 Siren I/O LAN Expander (IOEXP)
The Integriti 8 Zone LAN Expander Module connects directly to the Integriti ISC Controller's RS-485 LAN and provides an additional 8 Zone inputs and 2 Auxiliary outputs.

Up to 99 Zone Expander Modules can be connected to the Integriti RS-485 LAN or via IP LAN if connected with CLOE modules (Part 995093).

Integriti UniBus 8 Input Expander to suit ISC / IOEXP
The UniBus 8 input expander connects to an Integriti Security Controller (ISC), 8 zone expander or 16 zone expander module via the UniBus port. It provides an additional 8 zone inputs that support all Integriti zone types including multistate and counter types along with extra detector power supply connections (DET+) to simplify device wiring.

Integriti UniBus 8 Relay Output Expander to suit ISC / IOEXP
The UniBus 8 relay output expander board provides eight independent, high current normally open or normally closed relay outputs, offering a general purpose interface in applications such as warning devices (strobes, etc.), building automation, process control and access control. The board is connected directly to the host module or another UniBus Board via the UniBus cable supplied.

Inception to T4000 Security Communicator Interface Cable
This cable is designed to connect the T4000 (IR-998530) or T4000 Lite (IR-998530LT) Communicator to the USB port on the Inception Controller.

Integriti Extra Large Powered Enclosure with 3 Amp Power Supply
Designed for our Integriti Module PCBs, the Low Profile Metal Enclosures present a modular, application oriented solution to suit a variety of installation requirements. The enclosures are designed to minimise necessary wall space and simplify the practice of selecting and installing enclosures.

Multipath T4000 Lite 4G, Dual Sim, 3 Inputs, 3 Outputs, (Telstra/Optus)
The Multipath-IP T4000 Lite features the same highly advanced feature set as the original T4000, only in a smaller form factor, while packing more inputs and outputs. It's on board battery and PSTN dial through functions are not fitted to the device, which is a great way to retrofit existing systems from an existing battery-backed alarm system. With its tiny footprint, the new T4000 Lite should fit into existing alarm security cabinets.

12V 7.0Ah Sealed Lead Acid Battery
This Battery is a general purpose 12V 7Ah sealed lead acid (SLA) battery with a 5 year floating design life that meets both IEC and JIS standards. It is suitable for use in a wide range of domestic and commercial applications such as mobility, UPS, fire and security systems.
Product Specifications
Inner Range EliteX Standard Keypad
Physical
Housing Dimensions 152h x 90w x 18d mm
Installation Environment 0 Degrees - 50Degrees C @ 15% to 85% relative humidity (non-condensing)
Electrical
Input Voltage 11V - 14V DC
Operational Current at 13.7V DC 14.4mA (Back-light & LEDS off), 42mA (Back-light & LEDS max brightness)
Operations Current @ 13.7V DC SIFER Model 46mA (Back-light & LEDS off), 186mA (Peak, Back-light & LEDS max brightness)
Auxiliary Open Collector Output Current 18VDC, 500mA maximum each (PTC protected)
Display & Indicator Brightness
Display/ Keypad Variable brightness via programming (Can be turned off)
LED Indicators Variable brightness via programming Indicators & I/Os
LED Indicators 8
Aux Outputs (Open collector) 2
Universal I/Os 2 (Input mode is compatible with original Elite, or EOL/Multi-state compatible)
Inception Controller
Case Material ABS plastic<
Dimensions 205mm x 94mm x 36mm
Shipping Weight (gross) 1.2kg
Installation Environment 0°C-50°C @ 15%-90% relative humidity (non-condensing)
Power Source
- To “DC IN” (recommended):

- To “BATT” (alternate method):

18V to 24VDC 2.5A (e.g. the supplied 24V 2.5A PSU)
Note: A 12V, SLA Battery of 7AH to 18AH capacity must be connected to 'BATT' input.

12.8V-14VDC 2.8A (e.g. a separate external battery-backed power supply)
Note: "DC IN" should not be connected when powered via the BATT connection
Battery (supplied separately) 12 Volt Sealed Lead-Acid (gel) type - 7 to 18 Amp-Hour
Idle Current Consumption
- DC IN: (24V DC)
- BATT: (DC IN = 0V)
Note: Does not include battery charging or current required by any peripheral devices.
60mA (85mA with Ethernet connected)
110mA (150mA with Ethernet connected)
Additional Current Required For:
- Built-in Relays: (out 1 ~ out 4)
- Inception WiFi Adapter:
- Inception 4-Port USB Hub:
25mA per relay (33mA when Controller powered from "BATT" input)
25mA (40mA when Controller powered from "BATT" input)
20mA (40mA when Controller powered from "BATT" input)
Not including current required by any device connected to a USB Port
Power Supply Outputs:
- V OUT (4-PIN):
- V OUT (2-PIN):
- LAN +:
- READER +:
- USB 2.0:
- Maximum Combined Current - All Outputs
See notes 1 & 2 below
13.4VDC +/-150mV 750mA max
13.4VDC +/-150mV 1.5A max
13.4VDC +/-150mV 350mA max
13.4VDC +/-150mV 1A max
5VDC 500mA max
2.5 A
Battery Charger Output Voltage: 13.75VDC / Output Current: Up to 500mA
Typical Battery Backup Time:

- 7AH Battery:
- 18AH Battery:
- 18AH Battery:
With Ethernet or Wi-Fi + 1 LCD Terminal + up to 200mA for other devices.
16 Hours
40 Hours
24 Hours Configuration as above but up to 500mA for other devices.
AC Fail Detect (on "DC IN"): 16 Hours
Output Fuses: 40 Hours
Battery Input Fuse: 24 Hours Configuration as above but up to 500mA for other devices.
Battery Deep Discharge Protection Activated: 10.4V / Restored: 12.5V
Zone Inputs: 8
Relay Outputs: 4 (“OUT1-4”)
Relay Contact Rating: 5A 30VDC or AC (See note 2 below)
Indicator LED’s: 11
Alarm Reporting Formats: ContactID or IR-fast (via T4000 or SkyTunnel)
Physical
Enclosure Options XSmall - 252(L) x 263(W) x 85(D) (mm): Part# 995200XS
Small - 252(L) x 358(W) x 85(D) (mm): Part# 995200PE2 or 995200PE3
Medium - 460(L) x 358(W) x 85(D) (mm): Part# 995201PE2, 995201PE3 or 995201PE8
XLarge - 702(L) x 358(W) x 85(D) (mm): Part# 995203PE2, 995203PE3 or 995203PE8
WideBody - 580(L) x 510(W) x 95(D) (mm): Part# 995204PE3 or 995204PE8
Rack Mount - 2RU 680(L) x 420(W) x 85(D) (mm): Part# 995220PE2, 995220PE3 or 995220PE8
PCB Size Code Integriti "B" size
PCB Dimensions 200(L) x 94(W) x 45(D) (mm)
Shipping Weight: 260grams (Circuit Board and Accessories only)
Installation Environment 0°C - 70°C @15% - 90% Relative humidity (non-condensing)
Electrical (For PCB Only)
Power Supply Input 11V to 14VDC
Current Consumption 60mA standby. 100mA with both Aux relays on
NOTE: Current consumption does not include the current required by detectors or other external devices such as buzzers, lamps or any device attached to the DET+, LAN+ and UniBus connections
Contact Ratings
Aux Relays 2 Amps @ 30VDC
Connections
Zone Inputs 8 x Multistate Zone Inputs
Aux Outputs 2 x Relay Output NO|COM|NC
Cabinet Tamper 2 pin connection for cabinet tamper switch
UniBus Port 1 x UniBus Host expansion port
RS-485 LAN 1, Includes LAN+, LAN-, A, B. (LAN addressing set via DIP switches)
Siren Outputs 1 x Internal & 1 x External variable tone Siren Outputs*
Power Supply 1 x Integriti External Power Supply Connection
Power Outputs 4 x 13.75Vdc nominal outputs (DET+/DET- Detector Power)
External Power Supply Monitoring (Compatible with IR SMART PSU Devices)
AC Fail External PS AC Fail
Low Battery External PS Low Battery
LAN Fuse External PS LAN Fuse
Detector Fuse External PS Detector Fuse
Low Volts External PS Low Volts
PSU Fail External PS Fail
12V 7.0Ah Sealed Lead Acid Battery
Cells Per Unit 6
Voltage Per Unit 12
Capacity 6.5Ah@20hr-rate to 1.75V per cell @25 C
Weight Approx. 1.9 Kg
Max. Discharge Current 65A (5 sec)
Internal Resistance Approx. 35 mΩ
Operating Temperature Range Discharge: -20 ~60 °Charge: 0 °C~50°C Storage: -20 C~60 C 0°C
Normal Operating Temperature Range 25 C+/-5 C
Float charging Voltage 13.7 to 13.9 VDC/unit Average at 25 C
Recommended Maximum Charging Current Limit 2.0 A
Equalization and Cycle Service 14.6 to 14.8 VDC/unit Average at 25 C
Self-Discharge Valve Regulated Lead Acid (VRLA) batteries can be stored for o more than 6 months at 25 C. Self f-discharge ratio less than 3% o per month at 25 C. Pleas e charge bat teries before using
Terminal Faston Tab 187(F1)/Faston tab 250(F2)
Constainer Material A.B.S. (UL94-HB) , Flammability resistance of UL94-V2 can be available upon request.
Dimensions 151(L) 65(W) 100(H)
ModelDescriptionPriceStock
IK-INC7 Controller Kit 7, Large Enclosure, Battery, T4000 Lite, Expander & Relay $2,837.45
Call
Add to Cart
Product Accessories
Not all accessories and consumables are listed on our website. Please contact one of our experts using the 'Ask an Expert' form or call us on 1300 737 998 if you don't find what you're looking for.
FilenameSize
PDF Document 995203xx Datasheet.pdf 798KB Download
PDF Document 996515PCBK Datasheet.pdf 2MB Download
PDF Document 996500PCBK Datasheet.pdf 2MB Download
PDF Document 996300AU Datasheet.pdf 2MB Download
PDF Document 995400 Datasheet.pdf 1MB Download
PDF Document 998535 Datasheet.pdf 907KB Download
PDF Document 1200 Safety Datasheet.pdf 4MB Download
Product Videos
No videos found for this product.

Please contact our team for more information using the 'Ask an Expert' form or call us on 1300 737 998.

Contact our Team
Warehouse Locations
Warehouse Locations
NSW
  • Huntingwood 2148
  • Rosehill 2142
  • Rydalmere 2116

QLD
  • Acacia Ridge 4110
  • Tingalpa 4173

VIC
  • Box Hill 3128

WA
  • Burswood 6100

Related Products

Inner Range 996300AU Inner Range 996300AU

Access Control > Controllers

Inception IK-INC1 Inception IK-INC1

Access Control > Controllers

Inception IK-INC3 Inception IK-INC3

Access Control > Controllers

Fast Delivery
Courier Delivery
Express Courier Delivery

Most of our shipments are delivered using Australian courier companies such as Toll, Star Track Express, TNT or Border Express. Over 90% of orders are delivered within 2 business days.

Click and Collect
Click & Collect

Contact our sales team to see if the item you want to purchase is available to collect from the warehouse nearest to you.

International Delivery
International Delivery

We have many international clients. Contact our sales team for delivery costs and times.

Cost-effective solutions to suit your business needs

POSMarket can provide your business with the hardware, software, services and consumables you need to take your business to the next level. We can develop custom software for your next project or customise a solution from off-the-shelf software to suit your needs.

Request a Consultation Today