Part number 995036PCB&K | |
Physical | |
Cabinet Dimensions | 460(L) x 358(W) x 85(D) (mm) |
Installation Environment | 0°C - 40°C @15 - 85% Relative humidity (non-condensing) |
Electrical | PCB Versions; Transformer Versions |
Mains Input Voltage | N/A; 240VAC 50Hz |
Mains Input Current | N/A; Max 500mA |
Input Voltage to PCB | 16-18VAC; 16-18VAC |
Total Current Limit | Power supply source dependent 3A |
Recommended current allowance for battery charging | N/A; 300mA |
Available Current (for detectors, Power supply aux’s, relays, local LAN etc). | Source dependent; 2A |
All versions | |
Fuse Protection | Separate fuses for DET+, LAN, Locks & Readers |
Operational Current (no peripherals connected) | |
Intelligent 2DAM | 145mA (Both lock aux’s on: 240mA) |
- Plug-on Reader Expander | Add 20mA |
- 2 Door Expander Board | Add 30mA (Both lock aux’s on: 120mA) |
Inputs | |
Zone Inputs | 8 General purpose Zone Inputs |
Door Inputs | Door reed, REX, REN, Arm & tongue sense per door |
Reader Ports | 2 (Expandable to 8) |
Outputs | |
Relays | 2 (Expandable to 4, typically used for door locks) |
Outputs (open collector) | 14 expandable to 20 (8 General purpose; separate valid, invalid and DOTL output for each door) |
2 Door Expander Board 2 Door Expander Board | |
Electrical Specifications | |
Power Supply Input | From host Intelligent 2 Door Access Module. |
Reader Head Supply O/P | 5V or 13.75V DC 300mA maximum per Reader. |
Current Consumption | 30mA standby. Lock Auxiliaries: 45mA per Relay for Unlocked state. (Does NOT include current drawn by peripheral devices. e.g. Readers, Locks, Sounders, Detectors, etc.) |
NOTE: Small Prox Reader (~5-10cm range): Allow 50-120mA. Standard Prox Reader (~15cm range): Allow 120-180mA. These values are general approximations. See information supplied with Reader for actual current consumption. | |
Lock Relay | Contact rating: 30 V DC. 1 Amp maximum. |
Fuse Protection | Lock Power: 1A. Slow Blow M205 (20mm) |
Reader Power | 0.5A. Fast Blow M205 (20mm) ALWAYS REPLACE FUSES WITH SAME FUSE TYPE AND VALUE |
Maximum cable length | Europe Only. To meet EN standard 50130-4, cables connected to this device must be less than 30 metres in length. |
Physical Specifications | |
PCB size | 200mm x 94mm |
Operating Environment | 0° to 40° Celsius and 15% to 80% Relative humidity (non-condensing) |
Model | Description | Price | Stock | |
---|---|---|---|---|
IK-995035D4 | Concept 4000 Intelligent 4-Door Access Module Kit | $1,962.54 | Add to Cart |
Filename | Size | ||
---|---|---|---|
995035 Datasheet.pdf | 393KB | Download | |
995035 Installation Guide.pdf | 2MB | Download | |
995036PCBK Installation Guide.pdf | 1MB | Download |
Access Control > LAN Media, Module, Unibus
Access Control > LAN Media, Module, Unibus
Access Control > LAN Media, Module, Unibus
Most of our shipments are delivered using Australian courier companies such as Toll, Star Track Express, TNT or Border Express. Over 90% of orders are delivered within 2 business days.
Contact our sales team to see if the item you want to purchase is available to collect from the warehouse nearest to you.
We have many international clients. Contact our sales team for delivery costs and times.
POSMarket can provide your business with the hardware, software, services and consumables you need to take your business to the next level. We can develop custom software for your next project or customise a solution from off-the-shelf software to suit your needs.
Request a Consultation Today