This IK-996035W8PS(B-battery) contains the following components:
1 x Integriti Wide Body Powered Enclosure with 8 Amp (6.5A + 1.5A) Power Supply
1 x Integriti Expansion Plate Kit (Hinged) to suit 995204 Series Wide Body Enclosures
1 x Integriti Access Controller (IAC)
3 x Integriti UniBus 2 Door Expander (to suit ILAM / IAC)
1 x 12V 18Ah Sealed Lead Acid Battery
Integriti Wide Body Powered Enclosure with 8 Amp (6.5A + 1.5A) Power Supply
The wide body low profile powered enclosure is a locking general purpose ancillary enclosure. The powered option incorporates a battery-backed 12 Volt, 8 amp smart power supply (note: battery purchased separately). The enclosure can accommodate various combinations of Integriti controllers, modules and/or peripheral devices.
Integriti Expansion Plate Kit (Hinged) to suit 995204 Series Wide Body Enclosures
The Hinged Expansion Plate kit consists of a PCB Mounting Plate, Hinge Bracket and mounting hardware. It is designed to be fitted in an Integriti Wide Body Low Profile Enclosure allowing an additional layer of PCBs to be installed. When the Expansion plate is fitted, Integriti LAN Module and UniBus Module types up to 34mm in height can be mounted on the Expansion Plate and on the base of the enclosure under the Expansion Plate.
Integriti Access Controller (IAC)
This Access Controller is a state-of-the-art IP connected intelligent controller designed for access control applications. The IAC can directly manage up to 8 doors locally or up to 240 doors via RS-485 Sub-LAN expansion. All decision making is intelligently processed by the controller with no reliance on the system server (should the connection to the server be offline). The result is a solution that is incredibly quick, robust and highly available.
Integriti UniBus 2 Door Expander (to suit ILAM / IAC)
The UniBus 2 Door / 2 Reader Expander is designed for installation within the same tamper protected enclosure as its UniBus host module. The UniBus expander is connected directly to the host module or another UniBus device via the UniBus patch cable supplied.
12V 18Ah Sealed Lead Acid Battery
The Sealed lead acid battery is a general purpose 12V 18Ah sealed lead acid (SLA) battery with a 5 year floating design life that meets both IEC and JIS standards. It is suitable for use in a wide range of domestic and commercial applications such as mobility, UPS, Ffre and security systems.
WideBody Enclosure | |
Part number | 995204PE8 |
Physical | |
Enclosure Size | 595(L) x 512(W) x 95(D) |
Cable Entry Points | |
Top | 4 x 25mm Round Conduit Punch-outs 2 x 50x50mm Punch-out (with 25mm round inset) |
Base | 1 x 50x50mm Punch-out (with 25mm round inset) 1 x Power Entry 1 x 25x50 IEC lead entry point (Entry plate included) |
Back | Through wall cable entry behind main plate |
Power Supply | |
Powered Versions | 3/8Amp |
Hinged Expansion Plate | |
Dimensions | |
Mounting Plate | |
Length | 207 mm. |
Width | 240 mm. |
Bracket | Length: 225 mm. |
Height | 40 mm. |
Weight | 500 g |
PCB Assy Max Height | |
PCBs under plate | 34mm |
PCBs on plate | 34mm |
Access Controller (IAC) | |
Part number | 996035PCB&K |
Physical | |
Enclosure Dimensions | Medium - 460(L) x 358(W) x 85(D) (mm): Part# 995201PE3 or 995201PE8 - houses 1 x 996035+ 1 x 996535* XLarge - 702(L) x 358(W) x 85(D) (mm): Part# 995203PE3 or 995203PE8 - houses 1 x 996035 + up to 3 x 996535* WideBody - 580(L) x 510(W) x 95(D) (mm): Part# 995204PE3 or 995204PE8 - houses 1 x 996035 + up to 3 x 996535* Rack Mount - 2RU 680(L) x 420(W) x 85(D) (mm): Part# 995220PE3 or 995220PE8 - houses 1 x 996035 + up to 2 x 996535* |
PCB Size Code | Integriti "A" size |
PCB Dimensions | 200(L) x 200(W) x 45(D) (mm) |
Weight | 8.2 k.g. (In medium enclosure including mains transformer, 7AH battery and cover) |
Shipping Weight | 700grams (Circuit board & Accessories only) |
Installation Environment | 0°C - °C @15% - 90% Relative humidity (non-condensing) |
Electrical (For PCB Only) | |
Power Supply Input | : 11V to 14VDC (from external Integriti 3Amp or 8Amp SMART PSU) |
Current Consumption | 150mA standby, 220mA with on-board lock relays on, add 15mA for each active DOTL relay NOTE: Current consumption does not include the current required by readers or other external devices such as locks, buzzers, lamps or any device attached to the DOTL, Valid, Invalid, RS-485 Reader and UniBus connections |
Reader Head Supply O/P | 5V/13.8V DC, 300mA maximum per reader, 1Amp max for all readers |
Over Current Protection | Reader +V connections. Protected with self-resetting PTC’s |
Typical Reader Current | Allow 50~120mA for small Proximity Readers, 120~180mA for standard Proximity Readers (See reader datasheets for specific detail) |
RS-485 Reader LAN Current | Allow 75~150mA per SIFER reader connected |
Contact Ratings | |
Lock Relays | 5 Amps @ 30VDC |
DOTL Relays | 1 Amp @ 30VDC (Door Open Too Long output) |
Connections | |
Ethernet | 10/100 Ethernet Port |
USB Host | USB type "A" connection |
USB Slave | USB type "B" connection |
Port Zero | 5 Pin header for PC or Multipath-IP STU connection |
Smart Card Slot | For use with Smart Card (System Options Card) |
Lock 1 & 2 | Includes Lock+, Lock-, NO/COM/NC |
Door 1 & 2 | Includes Reed, 2 x 0v, Tongue, REN, REX, DOTL contacts |
Wiegand Reader Ports x 4: | Includes Valid, Invalid, 0V, Reader+, D1, D0, ARM |
Lock Power Input | Includes Lock+, Lock- connections from external PSU |
Cabinet Tamper | 2 pin connection for cabinet tamper switch |
Watchdog Output | 2 pin connection for remote monitoring system |
UniBus Port | 1 x UniBus Host expansion port for up to 6 local UniBus devices |
RS-485 LAN | 1, Includes LAN+, LAN-, A, B. (LAN addressing set via DIP switches) |
RS-485 Reader | 1 Includes LAN+, LAN-, A, B, Auto addressing for SIFER Readers |
External Power | 10way header block for connection to Integriti power supplies |
External Power Supply Monitoring (Compatible with IR SMART Power Supplies) | |
AC Fail | External PS AC Fail |
Low Battery | External PS Low Battery |
LAN Fuse | External PS LAN Fuse |
Detector Fuse | External PS Detector Fuse |
Low Volts | External PS Low Volts |
PSU Fail | External PS Fail |
UniBus 2 Door / 2 Reader Expander | |
Part number | 996535PCB&K |
Physical | |
PCB Size Code | Integriti “B†size |
PCB Size | 200(L) x 94(W) x 45(D) (mm) |
Height | 20(D) (mm) (45mm with UniBus cable connected) |
Shipping Weight | 290grams |
Installation Environment | 0ºC - 70ºC @15% - 90% Relative humidity (non-condensing) |
Electrical | |
Power Supply Input | 11V to 14VDC via host module |
Current Consumption | 40mA idle 110mA both lock relays on 135mA both lock & DOTL relays on NOTE: Current consumption does not include the current required by readers or other external devices such as locks, buzzers, lamps or any device attached to the DOTL, Valid, Invalid, RS-485 Reader and UniBus connections |
Over Current Protection | Reader +V connections. Protected with self-resetting PTC’s |
Contact Ratings | |
Lock Relays | 5 Amps @ 30VDC |
DOTL Relays | 1 Amp @ 30VDC (Door Open Too Long output) |
Connections | |
Lock 1 & 2 | Includes Lock+, Lock-, NO/COM/NC |
Door 1 & 2 | Includes Reed, 2 x 0v, Tongue, REN, REX, DOTL contacts |
Wiegand Reader 1 & 2 | Includes Valid, Invalid, 0V, Reader+, D1, D0, ARM |
Lock Power | Includes Lock+, Lock- connections from external PSU |
UniBus Port | 3 x UniBus connections for loop-through and connection to host module |
Power Considerations | The UniBus host module supplies static device current to all connected UniBus devices. |
Total current consumption is, therefore the sum of all | - Static Current of all connected UniBus devices - Static Current of host module - Host module battery charging current - Card Readers and Ancillary devices connected to DOTL, Valid & Invalid connections |
Lock Power Considerations | Lock power is supplied directly from an Integriti SMART PSU (Housed in the same enclosure) and is the sum of the maximum current required by all connected locking device hardware. |
Model | Description | Price | Stock | |
---|---|---|---|---|
IK-996035W8PS | IAC 8 Door Controller Kit includes 8 Amp SMART PSU | $6,078.88 | Add to Cart |
Filename | Size | ||
---|---|---|---|
![]() |
999027 Hinged Expansion Plate Installation Manual.pdf | 1MB | Download |
![]() |
1218 Lead acid batter Datasheet.pdf | 362KB | Download |
![]() |
12xxx Battery Safety Datasheet.pdf | 4MB | Download |
![]() |
996535PCBK Datasheet.pdf | 2MB | Download |
![]() |
996035 Datasheet.pdf | 3MB | Download |
![]() |
995204xx Datasheet.pdf | 908KB | Download |
Access Control > Controllers
Access Control > Controllers
Access Control > Controllers
Most of our shipments are delivered using Australian courier companies such as Toll, Star Track Express, TNT or Border Express. Over 90% of orders are delivered within 2 business days.
Contact our sales team to see if the item you want to purchase is available to collect from the warehouse nearest to you.
We have many international clients. Contact our sales team for delivery costs and times.
POSMarket can provide your business with the hardware, software, services and consumables you need to take your business to the next level. We can develop custom software for your next project or customise a solution from off-the-shelf software to suit your needs.
Request a Consultation Today