Integriti IK-996001

$3,396.25 (incl. GST)

POSMarket SKU: Z15969

IK-996001: ISC Controller Kit, 32 Zone, 8 Aux Relay

ISC Controller Kit, 32 Zone, 8 Aux Relay

Product Rating
Product Overview
This ISC Controller kit contains the following components:

1 x LAN Hub Board 9-Way RS485 Hub with DET Plus & Minus Power Hub
1 x Integriti Security Controller (ISC) in Medium Powered Enclosure
2 x Integriti UniBus 8 Input Expander to suit ISC / IOEXP
1 x Integriti UniBus 8 Relay Output Expander to suit ISC / IOEXP

LAN Hub Board 9-Way RS485 Hub with DET Plus & Minus Power Hub
The LAN Hub board makes it simple to keep your Concept LAN systematic and manageable. Four types of passive LAN HUBs are available for the distribution of Concept RS-485 networks and detector +/- power. The 995910 provides a single 9-Way HUB with additional terminals for detector positive and zero volt connections.
  • LED power indicator
  • Supplied complete with terminal blocks and mounting posts or self-adhesive mounts
  • 180mm(L) x 70mm(W)
Integriti Security Controller (ISC) in Medium Powered Enclosure
The Integriti Security Controller (ISC) is an IP-based master controller for the Integriti modular hardware system. Equipped with 16 Zone Inputs, 2 Auxiliary Relay Outputs, Power Supply, Ethernet Port, Modem, and Internal/External Siren outputs, the ISC can be used either stand-alone or expanded further via its UniBus and RS-485 Sub-LAN ports. The flexible, modular design of the ISC allows a single stand-alone controller to be expanded to form a network of IP or RS-485 expansion modules supporting up to 3,000 Zone Inputs, 3,000 Outputs, 250 Areas and over 1,000 Card Readers and 250 Doors. User capacity of up to 100,000 users is available, and capacity for 1,000,000 users is also available with the User Expansion Kit (Part. 996002L5)

Integriti UniBus 8 Input Expander to suit ISC / IOEXP
The UniBus 8 relay output expander board provides eight independent, high current normally open or normally closed relay outputs, offering a general purpose interface in applications such as warning devices (strobes, etc.), building automation, process control and access control. The board is connected directly to the host module or another UniBus Board via the UniBus cable supplied.

Integriti UniBus 8 Relay Output Expander to suit ISC / IOEXP
The UniBus 8 relay output expander board provides eight independent, high current normally open or normally closed relay outputs, offering a general purpose interface in applications such as warning devices (strobes, etc.), building automation, process control and access control. The board is connected directly to the host module or another UniBus Board via the UniBus cable supplied.
Product Specifications
Security Controller
Part number 996001AUPS
Physical
Enclosure Dimensions Medium size enclosure 460(L) x 358(W) x 85(D) (mm)
PCB Dimensions 200(L) x 200(W) x 45(D) (mm)
Shipping Weight 6.5kg (In medium enclosure with mains transformer and cover)
Installation Environment 0ºC - 50ºC @15% - 90% Relative humidity (non-condensing)
Cabinet Battery Bracket To suit 12V 7AH sealed lead acid battery
Electrical
Power Supply Type Type A (EN50131-1)
Transformer Input Voltage 240V AC -10% / +10%. 50Hertz
Transformer Output 16.5V AC. 50 Hertz
Current Consumption Maximum 500 mA from 240V AC Source
Fuse Protection Separate AC mains input fuse. 1.0 AMP Slow Blow M205 (20mm)
PCB AC Input Voltage 16 to 18V AC. 50/60 Hertz
Battery Charger Output 13.75VDC -0.15/+.05 V (AC power required)
12V, Sealed Battery Capacity Use 7.2AH or 18AH Lead Acid Type: Max 18AH
Battery Input Fuse 5 Amperes
Low Battery Alarm < 11V DC +/- 100mV
Deep Discharge Protection Activates at 10.4 V +/-100mV. Restores at 12.4V +/- 100mV
LAN “POS” & DET Output Voltage: 13.75V DC -0.15/+.05 V (When AC power Present)
LAN “POS” & DET+ Smartfuse trip current 2 Amperes
Maximum Ripple At maximum ancillary load current: < 200mV P-P / 75mV RMS
Low DC Voltage Alarm < 11V DC +/- 100mV
Siren Drivers Each capable of driving a 4 Ohm speaker (or 2 x 8 Ohm in parallel)
RS-485 & UniBus Parameters
UniBus In-Cabinet Expansion Up to 6 UniBus devices
RS-485 Sub-LAN Up to 250 RS-485 Sub-LAN Modules (maximum of 99 of any one type)
UniBus 8 Zone Expander
Part number 996500PCB&K
Physical
PCB Size Code Integriti “C” size
PCB Size 94(L) x 94(W) (mm)
PCB size including snap off strip 105(L) x 94(W) (mm)
Height 15(D) (mm) (28mm with UniBus cable connected)
Shipping Weight 100grams
Installation Environment 0ºC - 70ºC @15% - 90% Relative humidity (non-condensing)
Electrical
Power Supply Input 11V to 14V DC via host module
Static Current Consumption 75mA. (not including detector power)
DET Output Voltage 13.75V DC - sourced from host
DET+ Output Current Limited to available current from host
Connections
Zone Inputs 8
DET+ Out 4
UniBus Port 1
UniBus Loop-through Port 1
Connection to Host Module Via 270mm UniBus patch lead (supplied)
Power Considerations
The UniBus host module supplies DET+ current and static device current to all connected UniBus devices.
Total current consumption is, therefore the sum of all
- Static Current of all connected UniBus devices
- Static Current of host module
- Host module battery charging current
- Ancillary devices connected to all DET+ connections
- Ancillary devices connected to host module’s RS-485 LAN+
Integriti UniBus 8 Relay Output Expander
Pat number 996515PCB&K
Physical
PCB Size Code Integriti “C” size
PCB Size 94(L) x 94(W) (mm)
PCB Size Including Snap Off Strip 105(L) x 94(W) (mm)
Height 15(D) (mm) (28mm with UniBus cable connected)
Shipping Weight 161grams
Installation Environment 0ºC - 70ºC @15% - 90% Relative humidity (non-condensing)
Electrical
Power Supply Input 11V to 14V DC via host module
Static Current Consumption 45mA PLUS 16mA per relay
Approximately 175mA when all Relays are on.
Contact Rating
Maximum Switching Current 1.0 Amp @ 24VDC. or 0.5 Amp @ 50VAC (Per Relay)

NOTE: While the relays have higher AC Voltage contact ratings, the manufacturer does not recommend connection of AC voltages above 50VAC to the relay contact connections.
Connections
Relay Contacts 8 x NO/NC outputs - 24 Connections
UniBus Port 1
UniBus Loop-through Port 1
Connection to Host Module Via 270mm UniBus patch lead (supplied)
Power Considerations
The UniBus host module supplies DET+ current and static device current to all connected UniBus devices.
Total current consumption is, therefore the sum of all

- Static Current of all connected UniBus devices
- Static Current of host module
- Host module battery charging current
- Ancillary devices connected to all DET+ connections
- Ancillary devices connected to host module’s RS-485 LAN+
ModelDescriptionPriceStock
IK-996001 ISC Controller Kit, 32 Zone, 8 Aux Relay $3,396.25
Call
Add to Cart
Product Accessories
Not all accessories and consumables are listed on our website. Please contact one of our experts using the 'Ask an Expert' form or call us on 1300 737 998 if you don't find what you're looking for.
FilenameSize
PDF Document IR Power Accessories Datasheet.pdf 3MB Download
PDF Document 996001AUxx Datasheet.pdf 3MB Download
PDF Document 996500PCBK Datasheet.pdf 2MB Download
PDF Document 996515PCBK Datasheet.pdf 2MB Download
Product Videos
No videos found for this product.

Please contact our team for more information using the 'Ask an Expert' form or call us on 1300 737 998.

Contact our Team
Warehouse Locations
Warehouse Locations
NSW
  • Huntingwood 2148
  • Rosehill 2142
  • Rydalmere 2116

QLD
  • Acacia Ridge 4110
  • Tingalpa 4173

VIC
  • Box Hill 3128

WA
  • Burswood 6100

Related Products

Inner Range 996300AU Inner Range 996300AU

Access Control > Controllers

Inception IK-INC1 Inception IK-INC1

Access Control > Controllers

Inception IK-INC3 Inception IK-INC3

Access Control > Controllers

Fast Delivery
Courier Delivery
Express Courier Delivery

Most of our shipments are delivered using Australian courier companies such as Toll, Star Track Express, TNT or Border Express. Over 90% of orders are delivered within 2 business days.

Click and Collect
Click & Collect

Contact our sales team to see if the item you want to purchase is available to collect from the warehouse nearest to you.

International Delivery
International Delivery

We have many international clients. Contact our sales team for delivery costs and times.

Cost-effective solutions to suit your business needs

POSMarket can provide your business with the hardware, software, services and consumables you need to take your business to the next level. We can develop custom software for your next project or customise a solution from off-the-shelf software to suit your needs.

Request a Consultation Today