Security Controller | |
Part number | 996001AUPS |
Physical | |
Enclosure Dimensions | Medium size enclosure 460(L) x 358(W) x 85(D) (mm) |
PCB Dimensions | 200(L) x 200(W) x 45(D) (mm) |
Shipping Weight | 6.5kg (In medium enclosure with mains transformer and cover) |
Installation Environment | 0ºC - 50ºC @15% - 90% Relative humidity (non-condensing) |
Cabinet Battery Bracket | To suit 12V 7AH sealed lead acid battery |
Electrical | |
Power Supply Type | Type A (EN50131-1) |
Transformer Input Voltage | 240V AC -10% / +10%. 50Hertz |
Transformer Output | 16.5V AC. 50 Hertz |
Current Consumption | Maximum 500 mA from 240V AC Source |
Fuse Protection | Separate AC mains input fuse. 1.0 AMP Slow Blow M205 (20mm) |
PCB AC Input Voltage | 16 to 18V AC. 50/60 Hertz |
Battery Charger Output | 13.75VDC -0.15/+.05 V (AC power required) |
12V, Sealed Battery Capacity | Use 7.2AH or 18AH Lead Acid Type: Max 18AH |
Battery Input Fuse | 5 Amperes |
Low Battery Alarm | < 11V DC +/- 100mV |
Deep Discharge Protection | Activates at 10.4 V +/-100mV. Restores at 12.4V +/- 100mV |
LAN “POS†& DET | Output Voltage: 13.75V DC -0.15/+.05 V (When AC power Present) |
LAN “POS†& DET+ Smartfuse trip current | 2 Amperes |
Maximum Ripple | At maximum ancillary load current: < 200mV P-P / 75mV RMS |
Low DC Voltage Alarm | < 11V DC +/- 100mV |
Siren Drivers | Each capable of driving a 4 Ohm speaker (or 2 x 8 Ohm in parallel) |
RS-485 & UniBus Parameters | |
UniBus In-Cabinet Expansion | Up to 6 UniBus devices |
RS-485 Sub-LAN | Up to 250 RS-485 Sub-LAN Modules (maximum of 99 of any one type) |
UniBus 8 Zone Expander | |
Part number | 996500PCB&K |
Physical | |
PCB Size Code | Integriti “C†size |
PCB Size | 94(L) x 94(W) (mm) |
PCB size including snap off strip | 105(L) x 94(W) (mm) |
Height | 15(D) (mm) (28mm with UniBus cable connected) |
Shipping Weight | 100grams |
Installation Environment | 0ºC - 70ºC @15% - 90% Relative humidity (non-condensing) |
Electrical | |
Power Supply Input | 11V to 14V DC via host module |
Static Current Consumption | 75mA. (not including detector power) |
DET | Output Voltage 13.75V DC - sourced from host |
DET+ Output Current | Limited to available current from host |
Connections | |
Zone Inputs | 8 |
DET+ Out | 4 |
UniBus Port | 1 |
UniBus Loop-through Port | 1 |
Connection to Host Module | Via 270mm UniBus patch lead (supplied) |
Power Considerations The UniBus host module supplies DET+ current and static device current to all connected UniBus devices. | |
Total current consumption is, therefore the sum of all | - Static Current of all connected UniBus devices - Static Current of host module - Host module battery charging current - Ancillary devices connected to all DET+ connections - Ancillary devices connected to host module’s RS-485 LAN+ |
Integriti UniBus 8 Relay Output Expander | |
Pat number | 996515PCB&K |
Physical | |
PCB Size Code | Integriti “C†size |
PCB Size | 94(L) x 94(W) (mm) |
PCB Size Including Snap Off Strip | 105(L) x 94(W) (mm) |
Height | 15(D) (mm) (28mm with UniBus cable connected) |
Shipping Weight | 161grams |
Installation Environment | 0ºC - 70ºC @15% - 90% Relative humidity (non-condensing) |
Electrical | |
Power Supply Input | 11V to 14V DC via host module |
Static Current Consumption | 45mA PLUS 16mA per relay Approximately 175mA when all Relays are on. |
Contact Rating | |
Maximum Switching Current | 1.0 Amp @ 24VDC. or 0.5 Amp @ 50VAC (Per Relay) NOTE: While the relays have higher AC Voltage contact ratings, the manufacturer does not recommend connection of AC voltages above 50VAC to the relay contact connections. |
Connections | |
Relay Contacts | 8 x NO/NC outputs - 24 Connections |
UniBus Port | 1 |
UniBus Loop-through Port | 1 |
Connection to Host Module | Via 270mm UniBus patch lead (supplied) |
Power Considerations The UniBus host module supplies DET+ current and static device current to all connected UniBus devices. | |
Total current consumption is, therefore the sum of all | - Static Current of all connected UniBus devices - Static Current of host module - Host module battery charging current - Ancillary devices connected to all DET+ connections - Ancillary devices connected to host module’s RS-485 LAN+ |
Model | Description | Price | Stock | |
---|---|---|---|---|
IK-996001 | ISC Controller Kit, 32 Zone, 8 Aux Relay | $3,396.25 | Add to Cart |
Filename | Size | ||
---|---|---|---|
IR Power Accessories Datasheet.pdf | 3MB | Download | |
996001AUxx Datasheet.pdf | 3MB | Download | |
996500PCBK Datasheet.pdf | 2MB | Download | |
996515PCBK Datasheet.pdf | 2MB | Download |
Access Control > Controllers
Access Control > Controllers
Access Control > Controllers
Most of our shipments are delivered using Australian courier companies such as Toll, Star Track Express, TNT or Border Express. Over 90% of orders are delivered within 2 business days.
Contact our sales team to see if the item you want to purchase is available to collect from the warehouse nearest to you.
We have many international clients. Contact our sales team for delivery costs and times.
POSMarket can provide your business with the hardware, software, services and consumables you need to take your business to the next level. We can develop custom software for your next project or customise a solution from off-the-shelf software to suit your needs.
Request a Consultation Today